Technical Parameters

Model

CZ-UHA-
80(D~G)~2

CZ-UHA-
150(D~G)~2

CZ-UHA-
225(D~G)~2

CZ-UHA-
408(D~G)~2

CZ-UHA-
608(D~G)~2

CZ-UHA-
1000(D~G)~2

Internal Size (W×H×D) (mm)

400×500×400  

  500×600×500

  500×750×600

  600×850×800

  800×950×800

 1000×1000×1000

External Size (W×H×D) (mm)

600×1565×1830

700×1765×1930

700×2015×2030

800×2215×2230

1000×2415×2230

1200×2515×2430

Temperature Range

-70℃ ~ +150℃(D: -40℃ G: -70℃)


Humidity Range

20% ~ 98%RH(10% ~ 98%RH / 5% ~ 98%RH / Is a special optional condition)

Heating Rate

≥ 3℃/min(Average, No load)


Cooling Rate

≥ 1℃/min(Average, No load)

Temperature/Humidity Deviation

±2℃(No load); +2%RH, -3%RH(Humidity>75%RH), ±5%RH(Humidity≤75%RH)


Temperature/Humidity Fluctuation

≤±0.5℃(No load);≤±3%RH(No load)

Temperature/Humidity Accuracy                                               

0.1℃; 0.1%RH


Internal and External Materials


Cold rolled steel plate baked paint,inner box made of SUS304#stainless steel

Insulation Material                                     

High temperature resistant high-density PUR insulator material


Cooling System


Air cooled/single-stage compressor (-20℃),Water-cooled/two-stage compressor (-40℃~-70℃)

Controller                                                              

Self developed or customized


Compressor


French Tecumseh/American Copeland

Power Supply

1φ 220VAC ± 10%, 50/60Hz & 3 φ 380VAC ± 10%, 50/60Hz

Function Configuration

Protective Device
● Non fuse switch
● Compressor overload protection switch
● High and low pressure protection switch for refrigerant
● Over humidity and over temperature protection switch
● Leakage protection,total power overload, short circuit protection
● Fault warning system
Accessories
● Silicone plug 1 piece
● Observation window
● 100mm test hole
● Lighting fixtures
● Video surveillance system(Purchase)
● APP mobile platform management(Purchase)

Meets the Test Standards

● GB/T 2423.1-2016 Low temperature test method Bb
● GB/T 2423.2-2008 High temperature test method Ab
● GB/T 2423.3-2016 Test Ca: Steady damp heat test method
● GB/T 2423.4-2008 Test Db: Alternating damp heat method
● GB/T 2424.5-2021 Environmental testing for electrical and electronic products Temperature test chamber performance confirmation
● GB/T 2424.6-2021 Environmental testing for electrical and electronic products Temperature and humidity test chamber performance confirmation
● GB/T 2424.7-2006 Environmental testing for electrical and electronic products TestA and B(with load)temperature test chamber measurement
● GJB 150.3A-2009  High temperature test
● GJB 150.4A-2009  Low temperature test
● GJB 150.9A-2009  Wet heat test